Ground power unit FCA-180

FCA-180MFrequency converters of FCA series are designed to supply aircrafts during preflight maintenance at the airport. They can also be used as a power unit of test benches, hangars and aircraft manufacturing plants.

Could be manufactured in mobile, stationary and aerobridge versions.
Can be manufactured both in standard complete set and also according to Customer’s special requirements and adjustments.
FCA-180 is intended to supply all types of commercial jets with  400 Hz frequency, 3×115/200 VAC voltage and output power up to 180 kVA.

FCA converters provide:
–   High quality of output three-phase sinusoidal voltage with frequency  400 Hz
–   High efficiency coefficient
–   Low power consumption

 

Main characteristics:

  • Smart operational TFT display
  • Full diagnostic turn-up test
  • Energy consumption metering system
  • Modularity
  • Maximum individual protection
  • Innovative design
  • Easy operation and maintenance
  • Total harmonic content not more 3.0 %
  • Outgoing 400 Hz 3 phase sinusoidal voltage high quality
  • High efficiency factor
  • Possibility of modification/adjustment in accordance to the Customer’s needs
  • Energy consumption low level

Technical characteristics:

Output parameters:
Rated output power, kVA 180
Rated output voltage phase/line, V 3 x 115/200
Output voltage frequency, Hz 400 ± 0,01%
Output voltage regulation accuracy, %:
– for balanced load ± 0,5
– for 30 % unbalanced load ± 0,5
Total harmonic content THDU, %
– linear load ≤2
– nonlinear load ≤2
Frequency stabilization accuracy, % ± 0,1
Voltage modulation, % ≤1
Phase symmetry, electrical degree:
– for balanced load 120 ± 1
– for 30 % unbalanced load 120 ± 1
Power factor 0,97
Range of load change, % 0 – 100
Crest factor 1,414 ± 0,03
Permissible overload, %:
– during 600 s 125
– during 30 s 200
– during 10 s 250
– during 1 s 300
Input parameters:
Supply main rated voltage, V 3×380 (400)
Supply main voltage permitted deviation, % ± 5
Supply nominal frequency, Hz 50
Supply main rated frequency, Hz ± 10
Power factor at 100 % load ≥0,97
Line Current Distortion at nominal load THDI, % ≤7
Power consumption:
– at a standby mode with switched off Power switch, W ≤90
– at a standby mode with switched on Power switch, W ≤300
– at no-load mode with running converter, kW ≤2,8
Overall efficiency at nominal rated, % ≥96
Power interruption Up to 50 ms
Starting current No, soft start
Miscellaneous:
Stationary:
Overall dimensions W x H x D, mm 800 х 1250 х 1500
Weight, kg ≤850
Mobile:
Overall dimensions with cart W x H x D, mm 1200 x 1350 x 2400
Weight with cart, kg ≤950
Ingress protection (converter module) IP55
Maximum ambient temperature, ºС plus 56
Minimal ambient temperature, ºС minus 52
Audible noise, 1m 55dBA
Relative humidity, % 0 to 100