Frequency converters of FCA series are designed to supply aircrafts during preflight maintenance at the airport. They can also be used as a power unit of test benches, hangars and aircraft manufacturing plants.
Could be manufactured in mobile, stationary and aerobridge versions.
Can be manufactured both in standard complete set and also according to Customer’s special requirements and adjustments.
FCA-180 is intended to supply all types of commercial jets with 400 Hz frequency, 3×115/200 VAC voltage and output power up to 180 kVA.
FCA converters provide:
– High quality of output three-phase sinusoidal voltage with frequency 400 Hz
– High efficiency coefficient
– Low power consumption
Main characteristics:
- Smart operational TFT display
- Full diagnostic turn-up test
- Energy consumption metering system
- Modularity
- Maximum individual protection
- Innovative design
- Easy operation and maintenance
- Total harmonic content not more 3.0 %
- Outgoing 400 Hz 3 phase sinusoidal voltage high quality
- High efficiency factor
- Possibility of modification/adjustment in accordance to the Customer’s needs
- Energy consumption low level
Technical characteristics:
Output parameters: | |
Rated output power, kVA | 180 |
Rated output voltage phase/line, V | 3 x 115/200 |
Output voltage frequency, Hz | 400 ± 0,01% |
Output voltage regulation accuracy, %: | |
– for balanced load | ± 0,5 |
– for 30 % unbalanced load | ± 0,5 |
Total harmonic content THDU, % | |
– linear load | ≤2 |
– nonlinear load | ≤2 |
Frequency stabilization accuracy, % | ± 0,1 |
Voltage modulation, % | ≤1 |
Phase symmetry, electrical degree: | |
– for balanced load | 120 ± 1 |
– for 30 % unbalanced load | 120 ± 1 |
Power factor | 0,97 |
Range of load change, % | 0 – 100 |
Crest factor | 1,414 ± 0,03 |
Permissible overload, %: | |
– during 600 s | 125 |
– during 30 s | 200 |
– during 10 s | 250 |
– during 1 s | 300 |
Input parameters: | |
Supply main rated voltage, V | 3×380 (400) |
Supply main voltage permitted deviation, % | ± 5 |
Supply nominal frequency, Hz | 50 |
Supply main rated frequency, Hz | ± 10 |
Power factor at 100 % load | ≥0,97 |
Line Current Distortion at nominal load THDI, % | ≤7 |
Power consumption: | |
– at a standby mode with switched off Power switch, W | ≤90 |
– at a standby mode with switched on Power switch, W | ≤300 |
– at no-load mode with running converter, kW | ≤2,8 |
Overall efficiency at nominal rated, % | ≥96 |
Power interruption | Up to 50 ms |
Starting current | No, soft start |
Miscellaneous: | |
Stationary: | |
Overall dimensions W x H x D, mm | 800 х 1250 х 1500 |
Weight, kg | ≤850 |
Mobile: | |
Overall dimensions with cart W x H x D, mm | 1200 x 1350 x 2400 |
Weight with cart, kg | ≤950 |
Ingress protection (converter module) | IP55 |
Maximum ambient temperature, ºС | plus 56 |
Minimal ambient temperature, ºС | minus 52 |
Audible noise, 1m | 55dBA |
Relative humidity, % | 0 to 100 |