400% overload within 2 seconds
Frequency converters of FCA series are designed to supply aircrafts during preflight maintenance at the airport. They can also be used as a power unit of test benches, hangars and aircraft manufacturing plants.
FCA-90S is intended to supply all types of aircrafts with 400 Hz frequency and 115/200 VAC voltage during preflight preparation and technical maintenance.
Can be manufactured in both standard complete set and also by Client’s special requirements and adjustments.
FCA converters provide:
- high quality of output three-phase sinusoidal voltage with frequency 400 Hz;
- high efficiency coefficient;
- low power consumption.
Main characteristics:
- Smart operational TFT display
- Full diagnostic turn-up test
- Energy consumption metering system
- Modularity
- Maximum individual protection
- Innovative design
- Easy operation and maintenance
- A380, B787 compatible
- Outgoing 400 Hz 3 phase sinusoidal voltage high quality
- High efficiency factor
- Energy consumption low level
Upon direct request converters are supplied with spare parts set for 2 years and 5 years.
Technical characteristics:
1. Output parameters | |
1.1 Rated output power, kVA | 90 |
1.2 Rated output voltage phase/line, V | 3 x 115/200 |
1.3 Output voltage frequency, Hz | 400 ± 0,001 |
1.4 Output voltage regulation accuracy, %: – for the balanced load – for 30 % unbalanced load |
±0.5 ±0.5 |
1.5 Total harmonic content, % | ≤2 |
1.6 Frequency stabilization accuracy, % | ±0.001 |
1.7 Voltage modulation, % | ≤1 |
1.8 Phase symmetry, electrical degree: – for the balanced load – for 30 % unbalanced load |
120±1 120±1 |
1.9 Power factor | from 0.8 to 1 |
1.10 Range of load change, % | 0-100 |
1.11 Voltage value change at 100 % load connection, % | ≤8 |
1.12 Permissible overload, %: – During 600 seconds – During 30 seconds – During 10 seconds – During 2 second |
150 200 250 400 |
1.13 Starting current | No, soft start |
2. Input parameters | |
2.1 Supply main rated voltage, V | 3×400 (380) |
2.2 Supply main permitted deviation, % | ±10 |
2.3 Supply main rated frequency, Hz | 60 |
2.4 Supply main permitted frequency deviation, % | ±10 |
2.5 Fuse maximum current, A | 200 |
2.6 Power factor at 100% load | ≥0.97 |
2.7 Power consumption at no-load mode, kW | ≤1 |
2.8 Overall efficiency, at load 35-90 kVA, % | ≥96 |
3. Ingress protection (electronic part) | IP55 |
4. Dimensions (WxHxD), mm | 600x1200x600 |
5. Weight, no more, kg | ≤365 |
Outside temperature conditions | +56 / -40 C |
Aqustic noise level (1 m) | 55 dB |
Humidity | 0 – 100% |