Tallinn

MOBILE FREQUENCY CONVERTER

FCA-90M Series
Compatible with small, medium and long-haul aircrafts
Touchscreen
Electricity metering system
Full diagnostic turn-up test
400% overload within 2 seconds
Designed to comply with RoHS and REACH requirements
Back to Catalog

Power units of FCA series are designed to supply aircrafts during preflight maintenance at the airport. They can also be used as a power unit of test benches, hangars and aircraft manufacturing plants.

FCA-90M is intended to supply all types of aircrafts with 400 Hz frequency and 3x115/200 VAC voltage during preflight preparation and technical maintenance.

Can be manufactured in both standard complete set and also by Client’s special requirements and adjustments.

• Smart operational TFT display
• Full diagnostic turn-up test
• Energy consumption metering system
• Modularity
• Maximum individual protection
• Innovative design
• Easy operation and maintenance
• Outgoing 400 Hz 3 phase sinusoidal voltage high quality
• High efficiency factor
• Energy consumption low level

Output parameters: 
Rated output power, kVA90
Rated output voltage phase/line, V3 x 115/200
Output voltage frequency, Hz400 ± 0,001
Output voltage regulation accuracy, %: 
   — for the balanced load± 0,5
   — for 30 % unbalanced load± 0,5
 Total harmonic content, % 
   — linear≤ 2
   — non-linear load≤ 2
Voltage modulation, %≤ 1
Phase symmetry, electrical degree: 
   — for the balanced load120 ± 1
   — for 30 % unbalanced load120 ± 1
Power factor0,8 – 1,0
Range of load change, %0 – 100
Voltage value change at 100 % load connection, %≤ 10
Crest factor1,414 ± 0,03
Permissible overload, %: 
   — during 600 seconds150
   — during 30 seconds200
   — during 10 seconds250
   — during 5 seconds300
   — during 2 second400
  
Input parameters: 
Supply main rated voltage, V3 x 400 (380)
Supply main permitted deviation, %± 15
Supply main rated frequency, Hz50/60
Supply main permitted frequency deviation, %± 10
Power factor at 100% load≥0.97
The total value of the harmonic distortion factor of the current at the input,%≤ 5
Power consumption: 
   — in standby mode with the switch off switch, W≤ 50
   — idling, kW≤ 1
Efficiency in nominal mode,%≥ 96
Power interruptiontill 25 ms
Starting currentno, soft start
  
Additional data: 
 Dimensions (WxHxD), mm1200 x 600 x 600
Weight, kg≤ 395
 Ingress protectionIP55
 Max temperature conditions, ºС+ 56
 Min temperature conditions, ºС- 40
Aqustic noise level (1 m)55 dB 
Humidity, %0-100
Other Products