FCA-90HC Series


High level of reliability and efficiency
Low power consumption
Compact design
Low noise level
Heavy duty design
Designed to comply with RoHS and REACH requirements
Back to Catalog
FCA-90HC converter is intended to supply of airplane’s on-board power system by 3-phase alternating current with 400 Hz frequency and 115/200 VAC voltage during preflight preparation and technical maintenance.
Consists of static frequency converter FCA-90H and automated cable winding device ACW-04.. Each device is functionally complete and can be joined with each other.
Can be manufactured in both standard complete set and also by Client’s special requirements and adjustments.
- High quality of output three-phase sinusoidal voltage with frequency 400 Hz.
- High efficiency coefficient.
- Low power consumption.
- Total distortion factor no more than 3%.
- Operating mode at a power of 90 kVA - 24/7.
- 12-pulse system configuration.
- Brand new schematics and technical solutions.
- Adaptable under any type of aircraft.
- Low noise level
- Possibility of modification/adjustment in accordance with the Client’s needs.
- Modular assembly (main frequency converter and cable winding device are jointed).
- Multifunctional remote control.
- Heavy duty design.
Output parameters: | |
Rated output power, kVA | 90 |
Rated output voltage phase/line, V | 3 x 115/200 |
Output voltage frequency, Hz | 400 ± 0,001 |
Output voltage regulation accuracy, %: | |
— for the balanced load | ± 0,5 |
— for 30 % unbalanced load | ± 0,5 |
Total harmonic content, % | |
— linear | ≤ 2 |
— non-linear load | ≤ 2 |
Voltage modulation, % | ≤ 1 |
Phase symmetry, electrical degree: | |
— for the balanced load | 120 ± 1 |
— for 30 % unbalanced load | 120 ± 1 |
Power factor | 0,3 – 1,0 |
Range of load change, % | 0 – 100 |
Crest factor | 1,414 ± 0,03 |
Permissible overload, %: | |
— during 600 seconds | 125 |
— during 30 seconds | 150 |
— during 10 second | 200 |
— during 1 second | 300 |
Input parameters: | |
Supply main rated voltage, V | 3 x 400 (380) |
Supply main permitted deviation, % | ± 15 |
Supply main nominal frequency, Hz | 50/60 |
Supply main rated frequency, Hz | ± 10 |
Power factor at 100 % load | ≥ 0,97 |
The total value of the harmonic distortion factor of the current at the input,% | ≤ 5 |
Power consumption: | |
— at a standby mode with switch off Power switch, W | ≤ 50 |
— at no-load mode, kW | ≤ 1 |
Overall efficiency, at nominal rated, % | ≥ 96 |
Power interruption | up to 25 ms |
Starting current | no, soft start |
Miscellaneous: | |
Overall dimentions, W x H x D, mm | 1600 x 800 x 1000 |
Weight, kg | ≤ 680 |
Ingress protection | IP55 |
Maximum ambient temperature, ºС | + 56 |
Minimum ambient temperature, ºС | - 40 |
Acoustic noise level at 1m | 55 dB, usually 50 dB |
Relative humidity, % | 0-95 |