FCA-90HC converter is intended to supply of airplane’s on-board power system by 3-phase alternating current with 400 Hz frequency and 115/200 VAC voltage during preflight preparation and technical maintenance.

Consists of static frequency converter FCA-90H and automated cable winding device ACW-04.. Each device is functionally complete and can be joined with each other. 

Can be manufactured in both standard complete set and also by Client’s special requirements and adjustments.

  • High quality of output three-phase sinusoidal voltage with frequency 400 Hz.
  • High efficiency coefficient.
  • Low power consumption.
  • Total distortion factor no more than 3%.
  • Operating mode at a power of 90 kVA - 24/7.
  • 12-pulse system configuration.
  • Brand new schematics and technical solutions.
  • Adaptable under any type of aircraft.
  • Low noise level
  • Possibility of modification/adjustment in accordance with the Client’s needs.
  • Modular assembly (main frequency converter and cable winding device are jointed).
  • Multifunctional remote control.
  • Heavy duty design.
Output parameters: 
Rated output power, kVA90
Rated output voltage phase/line, V3 x 115/200
Output voltage frequency, Hz400 ± 0,001
Output voltage regulation accuracy, %: 
   — for the balanced load± 0,5
   — for 30 % unbalanced load± 0,5
Total harmonic content, % 
   — linear≤ 2
   — non-linear load≤ 2
Voltage modulation, %≤ 1
Phase symmetry, electrical degree: 
   — for the balanced load120 ± 1
   — for 30 % unbalanced load120 ± 1
Power factor0,3 – 1,0
Range of load change, %0 – 100
Crest factor1,414 ± 0,03
Permissible overload, %: 
   — during 600 seconds125
   — during 30 seconds150
   — during 10 second200
   — during 1 second300
  
Input parameters: 
Supply main rated voltage, V 3 x 400 (380)
Supply main permitted deviation, % ± 15
Supply main nominal frequency, Hz 50/60
Supply main rated frequency, Hz ± 10
Power factor at 100 % load ≥ 0,97
The total value of the harmonic distortion factor of the current at the input,% ≤ 5
Power consumption: 
    — at a standby mode with switch off Power switch, W ≤ 50
    — at no-load mode, kW ≤ 1
Overall efficiency, at nominal rated, % ≥ 96
Power interruptionup to 25 ms
Starting currentno, soft start
  
Miscellaneous: 
Overall dimentions, W x H x D, mm 1600 x 800 x 1000
Weight, kg ≤ 680 
Ingress protectionIP55
Maximum ambient temperature, ºС+ 56
Minimum ambient temperature, ºС- 40
Acoustic noise level at 1m55 dB, usually 50 dB
Relative humidity, %0-95