Tallinn

STATIONARY COMBINED GROUND POWER UNITS

FCA/AR Series
High efficiency
Low energy consumption
Compact design
Low noise level
Robust design
Designed to comply with RoHS and REACH requirements
Back to Catalog

Combined power unit FCA-90/AR-600A consists of frequency converter 400 Hz and 28 V rectifier. The unit is designed to supply aircafts and helicopters during preflight maintenance at the airport. It can also be used as a power unit of test benches, hangars and aircraft manufacturing plants.

Can be manufactured both in standard complete set and according to Customer’s special requirements and adjustments.

Could be manufactured in mobile, stationary and aerobridge versions. 

Combined power unit  FCA/AR provide:

  • High quality of output voltage of onboard aircraft systems
  • High efficiency coefficient
  • Low power consumption
  • Total harmonic content not more 2.0 %
  • 24/7 operating mode
  • 12-pulse system configuration
  • TFT display
  • Adaptable under any type of aircraft
  • High level of reliability
  • Low noise level
  • Compact design
  • Suitable for use in any climate
Output parameters: FCA-30/45/60/90
Rated output power, kVA30/45/60/90
Rated output voltage phase/line, V3×115/200
Output voltage frequency, Hz400
Output voltage regulation accuracy, %: 
– for balanced load±0,5
– for 30 % unbalanced load±0,5
Total harmonic content THDU % 
– linear load≤2
– nonlinear load≤2
Frequency stabilization accuracy, %±0.001
Voltage modulation, %≤1
Phase symmetry, electrical degree: 
– for balanced load120±1
– for 30 % unbalanced load120±1
Range of load change, %0-100
Crest factor1,414±0,03%
Permissible overload, %: 
  
– within 600 s150
– within 30 s200
– within 10 s300
– within 2 s400
Rectifier output parameters: AR-400/600/1200A 
Rated output voltage, V28,0
Output voltage stabilization accuracy(< 0,5%)
Pulsation coefficient of output voltage(<1%)
Rated output current, A600 А
Quantity of outputs1
Permissible current overload, A: 
– within 30 s1200
– within 10 s1800
– within 5 s2100
– within 2 s2400
Input parameters: 
Supply main rated voltage, V3x230(220)/400(380)
Supply main voltage permitted deviation, %±15
Supply nominal frequency, Hz60/50
Supply main rated frequency, %±10
Line Current Distortion at nominal load THDI, %≤5
Power factor at 100 % load≥0,97
Power consumption: 
– at a standby mode with switched off Power switch, W≤50
– at no-load mode with running converter, kW≤1
Power interruptionup to 50ms
Overall efficiency, %≥96
Starting currentno, soft start
Miscellaneous: 
Overall dimensions, W x H x D, mm600× 1500× 600
Weight, kg≤660
Ingress protection (converter module)IP55
Audible noise55 dB
Ambient temperature range-52°С  +56°С
Relative humidity, %0 to 100
Other Products