Power unit FCA-90HC (aerobridge)
High level of reliability and efficiency
Low power consumption
Compact design
Low noise level
Heavy duty design
Designed to comply with RoHS and REACH requirements
FCA-90-12HC is intended to supply of airplane’s on-board power system by 3-phase alternating current with 400 Hz frequency and 115/200 VAC voltage during preflight preparation and technical maintenance.
Consists of static frequency converter FCA-90-12H and automated cable winding device ACW-02. Each device is functionally complete and can be joined with each other.
Can be manufactured in both standard complete set and also by Client’s special requirements and adjustments.
- High quality of output three-phase sinusoidal voltage with frequency 400 Hz.
- High efficiency coefficient.
- Low power consumption.
- Total distortion factor no more than 3%.
- Operating mode at a power of 90 kVA - 24/7.
- 12-pulse system configuration.
- Brand new schematics and technical solutions.
- Adaptable under any type of aircraft.
- Low noise level
- Possibility of modification/adjustment in accordance with the Client’s needs.
- Modular assembly (main frequency converter and cable winding device are jointed).
- Multifunctional remote control.
- Heavy duty design.
Output parameters: | |
Rated output power, kVA | 90 |
Rated output voltage phase/line, V | 3 x 115/200 |
Output voltage frequency, Hz | 400 ± 0,001 |
Output voltage regulation accuracy, %: | |
— for the balanced load | ± 0,5 |
— for 30 % unbalanced load | ± 0,5 |
Total harmonic content, % | |
— linear | ≤ 2 |
— non-linear load | ≤ 2 |
Voltage modulation, % | ≤ 1 |
Phase symmetry, electrical degree: | |
— for the balanced load | 120 ± 1 |
— for 30 % unbalanced load | 120 ± 1 |
Power factor | 0,3 – 1,0 |
Range of load change, % | 0 – 100 |
Crest factor | 1,414 ± 0,03 |
Permissible overload, %: | |
— during 600 seconds | 125 |
— during 30 seconds | 150 |
— during 10 second | 200 |
— during 1 second | 300 |
Input parameters: | |
Supply main rated voltage, V | 3 x 400 (380) |
Supply main permitted deviation, % | ± 15 |
Supply main nominal frequency, Hz | 50/60 |
Supply main rated frequency, Hz | ± 10 |
Power factor at 100 % load | ≥ 0,97 |
The total value of the harmonic distortion factor of the current at the input,% | ≤ 5 |
Power consumption: | |
— at a standby mode with switch off Power switch, W | ≤ 50 |
— at no-load mode, kW | ≤ 1 |
Overall efficiency, at nominal rated, % | ≥ 96 |
Power interruption | up to 25 ms |
Starting current | no, soft start |
Miscellaneous: | |
Overall dimentions, W x H x D, mm | 1600 x 800 x 1000 |
Weight, kg | ≤ 680 |
Ingress protection | IP55 |
Maximum ambient temperature, ºС | + 56 |
Minimum ambient temperature, ºС | - 40 |
Acoustic noise level at 1m | 55 dB, usually 50 dB |
Relative humidity, % | 0-95 |
Portfolio
FCA-90M
FCA-90/AR-600M
AR-2×600
FCA-90М
FCA90/AR-2х600-М
FCA-90S
FCA-90S
FCA-90S, FCA-15
AR-400, FCA-63
FCA-100
FCA-63/AR-400, FCA-90S, FCA-120S
AR-400, FCA-90S
AR-400, FCA-90S, FCA-30
FCA-10-6S
FCA-90/АВ-1-600х28,5 (mobile)
FCA-90-12M (mobile)
Any questions?
Contact us, we will be happy to answer!
Phone: +372 6228 395